Calpeda MXV-B 50 vertical multi-stage close coupled pumps in stainless steel 3x400V

Calpeda MXV-B 50 vertical multi-stage close coupled pumps in stainless steel 3x400V

Vertical Multi-Stage Close Coupled Pumps See more

Technical Specifications

Maximum flow [l/min]
400
Maximum head [m]
27.90 - 141
Input voltage [V]
3x400
Power output - P2 [kW]
1.50 - 7.50

Show all Tech Specs

on demand check availability

from 1,288.29 VAT included

Choose variant

Delivery accross EU within 3-7 business days %

Brand:
CALPEDA
Category:
Horizontal surface pumps
Product No.:
MAS001699

Product variants

  • Technical Specifications
  • Product No.
  • Maximum flow [l/min]
  • Maximum head [m]
  • Input voltage [V]
  • Power output - P2 [kW]
  • Suction port ["]
  • Rated flow [l/m]
  • Rated head [m]
  • Delivery port ["]
  • Maximum suction lift [m]
  • Drinking water certificate
  • Maximum current [A]
  • Maximum liquid temperature [°C]
  • Maximum pressure [bar]
  • Protection [IP]
  • Automatic thermal protection
  • Dry run protection
  • Off switch
  • Speed ​​control
  • Capacitor
  • Pump design
  • Impeller material
  • Construction
  • Availability
  • Price

next

Variant Product No.

Availability

Price (VAT incl.)

Maximum flow [l/min]
400
Maximum head [m]
27.90
Input voltage [V]
3x400
Power output - P2 [kW]
1.50
Suction port ["]
DN50
Rated flow [l/m]
267
Rated head [m]
19.80
Delivery port ["]
DN50
Maximum suction lift [m]
9
Drinking water certificate
YES
Maximum current [A]
4.30
Maximum liquid temperature [°C]
90
Maximum pressure [bar]
16
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
Maximum flow [l/min]
400
Maximum head [m]
43.60
Input voltage [V]
3x400
Power output - P2 [kW]
2.20
Suction port ["]
DN50
Rated flow [l/m]
267
Rated head [m]
31.30
Delivery port ["]
DN50
Maximum suction lift [m]
9
Drinking water certificate
YES
Maximum current [A]
5.30
Maximum liquid temperature [°C]
90
Maximum pressure [bar]
16
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
Maximum flow [l/min]
400
Maximum head [m]
58
Input voltage [V]
3x400
Power output - P2 [kW]
3
Suction port ["]
DN50
Rated flow [l/m]
267
Rated head [m]
43.70
Delivery port ["]
DN50
Maximum suction lift [m]
9
Drinking water certificate
YES
Maximum current [A]
6.60
Maximum liquid temperature [°C]
90
Maximum pressure [bar]
16
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
Maximum flow [l/min]
400
Maximum head [m]
72.50
Input voltage [V]
3x400
Power output - P2 [kW]
4
Suction port ["]
DN50
Rated flow [l/m]
267
Rated head [m]
54.70
Delivery port ["]
DN50
Maximum suction lift [m]
9
Drinking water certificate
YES
Maximum current [A]
9.60
Maximum liquid temperature [°C]
90
Maximum pressure [bar]
16
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
Maximum flow [l/min]
400
Maximum head [m]
85
Input voltage [V]
3x400
Power output - P2 [kW]
5.50
Suction port ["]
DN50
Rated flow [l/m]
267
Rated head [m]
63
Delivery port ["]
DN50
Maximum suction lift [m]
9
Drinking water certificate
YES
Maximum current [A]
10.80
Maximum liquid temperature [°C]
90
Maximum pressure [bar]
16
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
Maximum flow [l/min]
400
Maximum head [m]
99
Input voltage [V]
3x400
Power output - P2 [kW]
5.50
Suction port ["]
DN50
Rated flow [l/m]
267
Rated head [m]
73.50
Delivery port ["]
DN50
Maximum suction lift [m]
9
Drinking water certificate
YES
Maximum current [A]
10.80
Maximum liquid temperature [°C]
90
Maximum pressure [bar]
16
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
Maximum flow [l/min]
400
Maximum head [m]
115
Input voltage [V]
3x400
Power output - P2 [kW]
5.50
Suction port ["]
DN50
Rated flow [l/m]
267
Rated head [m]
86
Delivery port ["]
DN50
Maximum suction lift [m]
9
Drinking water certificate
YES
Maximum current [A]
10.80
Maximum liquid temperature [°C]
90
Maximum pressure [bar]
16
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
Maximum flow [l/min]
400
Maximum head [m]
129
Input voltage [V]
3x400
Power output - P2 [kW]
7.50
Suction port ["]
DN50
Rated flow [l/m]
267
Rated head [m]
97
Delivery port ["]
DN50
Maximum suction lift [m]
9
Drinking water certificate
YES
Maximum current [A]
14.30
Maximum liquid temperature [°C]
90
Maximum pressure [bar]
16
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
Maximum flow [l/min]
400
Maximum head [m]
141
Input voltage [V]
3x400
Power output - P2 [kW]
7.50
Suction port ["]
DN50
Rated flow [l/m]
267
Rated head [m]
105
Delivery port ["]
DN50
Maximum suction lift [m]
9
Drinking water certificate
YES
Maximum current [A]
14.30
Maximum liquid temperature [°C]
90
Maximum pressure [bar]
16
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage

Product description

Construction

Vertical multi-stage close coupled pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line).
All parts that come into contact with the liquid, including wet-end covers, are in chrome-nickel stainless steel with corrosionresistant bearing sleeves lubricated by the pumped liquid.

Applications

- For water supply systems.
- For clean non-explosive liquids, without solid, filamentary or abrasive matter and non-aggressive for stainless steel (with adaptation of sealing materials on request).
- A universal pump for civil and industrial use, for pressure-boosting systems, fire-extinguishing systems, high-pressure washing plants, irrigation, agricultural uses and sport installations.

Technical Specifications

Maximum flow [l/min]
400
Maximum head [m]
27.90 - 141
Input voltage [V]
3x400
Power output - P2 [kW]
1.50 - 7.50
Suction port ["]
DN50
Rated flow [l/m]
267
Rated head [m]
19.80 - 105
Delivery port ["]
DN50
Maximum suction lift [m]
9
Drinking water certificate
YES
Maximum current [A]
4.30 - 14.30
Maximum liquid temperature [°C]
90
Maximum pressure [bar]
16 - 16
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage

Product Safety Information

Company responsible for product safety:
Calpeda S.p.A.
Via Roggia di Mezzo 39, 36050 Montorso Vicentino, IT
e-mail: [email protected]