Calpeda NR4 65/250B/A 230/400V 3,0kW 1450rpm, in-line centrifugal pump

Close-coupled, single-impeller, centrifugal pumps; electric motor with extended shaft directly connected to the pump. See more

Technical Specifications

Maximum flow [l/min]
800
Maximum head [m]
19.90
Input voltage [V]
3x400
Power output - P2 [kW]
3

Show all Tech Specs

on demand check availability

Goods cannot be purchased online. These are either oversized goods with an individual price of transport or an assortment that can only be purchased on demand. If you are interested in the goods, contact us by email [email protected]

1,990.92 VAT included

Not sellable online

Delivery accross EU within 3-7 business days %

Brand:
CALPEDA
Category:
Surface pumps
Product No.:
ZB00065967
Sale group:
CECP
EAN:
8030485597902
Manuf. No.:
70MB1461000

Product variants

  • Technical Specifications
  • Product No.
  • Maximum flow [l/min]
  • Maximum head [m]
  • Input voltage [V]
  • Power output - P2 [kW]
  • Suction port ["]
  • Delivery port ["]
  • Maximum suction lift [m]
  • Maximum current [A]
  • Maximum liquid temperature [°C]
  • Protection [IP]
  • Automatic thermal protection
  • Dry run protection
  • Off switch
  • Speed ​​control
  • Capacitor
  • Pump design
  • Impeller material
  • Availability
  • Price

next

Variant Product No.

Availability

Price (VAT incl.)

Maximum flow [l/min]
267
Maximum head [m]
3.80
Input voltage [V]
3x400
Power output - P2 [kW]
0.25
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
0.80
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron
Maximum flow [l/min]
300
Maximum head [m]
4.70
Input voltage [V]
3x400
Power output - P2 [kW]
0.37
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
1.20
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron
Maximum flow [l/min]
333
Maximum head [m]
5.60
Input voltage [V]
3x400
Power output - P2 [kW]
0.37
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
1.20
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron
Maximum flow [l/min]
550
Maximum head [m]
4.10
Input voltage [V]
3x400
Power output - P2 [kW]
0.37
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
0.95
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron
Maximum flow [l/min]
630
Maximum head [m]
5.30
Input voltage [V]
3x400
Power output - P2 [kW]
0.55
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
1.50
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron

Calpeda NR4 65/125A/A 400V 0,75kW 1450rpm

Product No.: ZB00001852 Sale group: CECP EAN: 8030485905417 Manuf. No.: 70MB1122000

970.45 €

Maximum flow [l/min]
700
Maximum head [m]
6.30
Input voltage [V]
3x400
Power output - P2 [kW]
0.75
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
1.90
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron
Maximum flow [l/min]
700
Maximum head [m]
6.80
Input voltage [V]
3x400
Power output - P2 [kW]
0.75
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
1.90
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron
Maximum flow [l/min]
800
Maximum head [m]
9.70
Input voltage [V]
3x400
Power output - P2 [kW]
1.10
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
2.90
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron
Maximum flow [l/min]
700
Maximum head [m]
8.20
Input voltage [V]
3x400
Power output - P2 [kW]
1.10
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
2.90
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron
Maximum flow [l/min]
700
Maximum head [m]
11.40
Input voltage [V]
3x400
Power output - P2 [kW]
1.10
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
2.90
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron
Maximum flow [l/min]
700
Maximum head [m]
13.30
Input voltage [V]
3x400
Power output - P2 [kW]
1.50
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
3.50
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron
Maximum flow [l/min]
700
Maximum head [m]
14.50
Input voltage [V]
3x400
Power output - P2 [kW]
2.20
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
5
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron
Maximum flow [l/min]
700
Maximum head [m]
17.10
Input voltage [V]
3x400
Power output - P2 [kW]
2.20
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
5
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron
Maximum flow [l/min]
700
Maximum head [m]
13.70
Input voltage [V]
3x400
Power output - P2 [kW]
2.20
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
5
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron
Maximum flow [l/min]
800
Maximum head [m]
19.90
Input voltage [V]
3x400
Power output - P2 [kW]
3
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
6.40
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron
You are viewing this variant
Maximum flow [l/min]
800
Maximum head [m]
21.40
Input voltage [V]
3x400
Power output - P2 [kW]
4
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
8.30
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron

Product description

Applications

  • For clean liquids, without abrasives, which are non-aggressive for the pump materials (contents of solids up to 0.2%).
  • For heating, conditioning, cooling and circulation plants.
  • For civil and industrial applications.
  • When low noise operation is required (n = 1450 rpm).

Technical Specifications

Maximum flow [l/min]
800
Maximum head [m]
19.90
Input voltage [V]
3x400
Power output - P2 [kW]
3
Suction port ["]
DN65
Delivery port ["]
DN65
Maximum suction lift [m]
7
Maximum current [A]
6.40
Maximum liquid temperature [°C]
90
Protection [IP]
54
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
cast iron