Technical Specifications

Maximum flow [l/min]
150
Maximum head [m]
36 - 189
Input voltage [V]
without motor
Power output - P2 [kW]
0.75 - 4

Show all Tech Specs

on demand check availability

from 132.64 VAT included

Choose variant

Delivery accross EU within 3-7 business days %

Brand:
Franklin Electric
Category:
Submersible borehole pumps
Product No.:
MAS001492

Product variants

  • Technical Specifications
  • Product No.
  • Maximum flow [l/min]
  • Maximum head [m]
  • Input voltage [V]
  • Power output - P2 [kW]
  • Rated flow [l/m]
  • Rated head [m]
  • Delivery port ["]
  • Pump diameter ["]
  • Drinking water certificate
  • Float switch
  • Maximum liquid temperature [°C]
  • Maximum particle size [mm]
  • Maximum borehole diameter [mm]
  • Impeller material
  • Construction
  • Availability
  • Price

next

Variant Product No.

Availability

Price (VAT incl.)

Maximum flow [l/min]
150
Maximum head [m]
36
Input voltage [V]
without motor
Power output - P2 [kW]
0.75
Rated flow [l/m]
125
Rated head [m]
24
Delivery port ["]
2
Pump diameter ["]
4
Drinking water certificate
YES
Float switch
NO
Maximum liquid temperature [°C]
40
Maximum particle size [mm]
2
Maximum borehole diameter [mm]
95
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
150
Maximum head [m]
50
Input voltage [V]
without motor
Power output - P2 [kW]
1.10
Rated flow [l/m]
125
Rated head [m]
32
Delivery port ["]
2
Pump diameter ["]
4
Drinking water certificate
YES
Float switch
NO
Maximum liquid temperature [°C]
40
Maximum particle size [mm]
2
Maximum borehole diameter [mm]
95
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
150
Maximum head [m]
72
Input voltage [V]
without motor
Power output - P2 [kW]
1.50
Rated flow [l/m]
125
Rated head [m]
45
Delivery port ["]
2
Pump diameter ["]
4
Drinking water certificate
YES
Float switch
NO
Maximum liquid temperature [°C]
40
Maximum particle size [mm]
2
Maximum borehole diameter [mm]
95
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
150
Maximum head [m]
105
Input voltage [V]
without motor
Power output - P2 [kW]
2.20
Rated flow [l/m]
125
Rated head [m]
68
Delivery port ["]
2
Pump diameter ["]
4
Drinking water certificate
YES
Float switch
NO
Maximum liquid temperature [°C]
40
Maximum particle size [mm]
2
Maximum borehole diameter [mm]
95
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
150
Maximum head [m]
140
Input voltage [V]
without motor
Power output - P2 [kW]
3
Rated flow [l/m]
125
Rated head [m]
90
Delivery port ["]
2
Pump diameter ["]
4
Drinking water certificate
YES
Float switch
NO
Maximum liquid temperature [°C]
40
Maximum particle size [mm]
2
Maximum borehole diameter [mm]
95
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
150
Maximum head [m]
176
Input voltage [V]
without motor
Power output - P2 [kW]
3.70
Rated flow [l/m]
125
Rated head [m]
107
Delivery port ["]
2
Pump diameter ["]
4
Drinking water certificate
YES
Float switch
NO
Maximum liquid temperature [°C]
40
Maximum particle size [mm]
2
Maximum borehole diameter [mm]
95
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
150
Maximum head [m]
189
Input voltage [V]
without motor
Power output - P2 [kW]
4
Rated flow [l/m]
125
Rated head [m]
124
Delivery port ["]
2
Pump diameter ["]
4
Drinking water certificate
YES
Float switch
NO
Maximum liquid temperature [°C]
40
Maximum particle size [mm]
2
Maximum borehole diameter [mm]
95
Impeller material
noryl
Construction
centrifugal

Product description

APPLICATIONS

  • Municipal water works, fountains and waste water
  • Water distribution and pressure boosting
  • Irrigation and sprinkler systems, water treatment plants, filtration and reverse osmosis
  • Industrial cooling and processing
  • Mining industry, drainage and dewatering
  • Fire-fighting equipment
  • Water supply to and from tanks, reservoir and wells
  • Lifting and distribution of a wide range of liquids
  • Autoclave and cistern charge and discharge
  • Turf and landscape
  • Greenhouses and nurseries
  • Residential and farm wells and drainage
  • Food industry
  • General industry


FEATURES

  • Compact, reliable and suited to operate in horizontal position.
  • Built-in check valve to protect the pump against water hammer risk.
  • Floating impellers to grant a better performance and longer life for the pump against abrasion.
  • The hydraulic design is such to enhance the overall efficiency thus reducing energy consumption and making the pumping systems more cost effective.

Technical Specifications

Maximum flow [l/min]
150
Maximum head [m]
36 - 189
Input voltage [V]
without motor
Power output - P2 [kW]
0.75 - 4
Rated flow [l/m]
125
Rated head [m]
24 - 124
Delivery port ["]
2
Pump diameter ["]
4
Drinking water certificate
YES
Float switch
NO
Maximum liquid temperature [°C]
40
Maximum particle size [mm]
2
Maximum borehole diameter [mm]
95
Impeller material
noryl
Construction
centrifugal