PUMP INOX LINE STP-1010 4" 0.55kW 230V 2-wire motor PSM4M, submersible pump, 30m cable

4" stainless steel submersible pumps with Pumpa motor See more

Technical Specifications

Maximum flow [l/min]
50
Maximum head [m]
67
Input voltage [V]
230
Power output - P2 [kW]
0.55

Show all Tech Specs

on demand check availability

Goods cannot be purchased online. These are either oversized goods with an individual price of transport or an assortment that can only be purchased on demand. If you are interested in the goods, contact us by email [email protected]

368.90 VAT included

Not sellable online

Delivery accross EU within 3-7 business days %

Brand:
PUMPA
Category:
Submersible borehole pumps
Product No.:
ZB00068752
Sale group:
CEST
EAN:
8596455039518

Product variants

  • Technical Specifications
  • Product No.
  • Maximum flow [l/min]
  • Maximum head [m]
  • Input voltage [V]
  • Power output - P2 [kW]
  • Rated flow [l/m]
  • Rated head [m]
  • Delivery port ["]
  • Pump diameter ["]
  • Maximum immersion depth [m]
  • Drinking water certificate
  • Float switch
  • Maximum current [A]
  • Maximum liquid temperature [°C]
  • Cable length [m]
  • Protection [IP]
  • Automatic thermal protection
  • Dry run protection
  • Off switch
  • Speed ​​control
  • Capacitor
  • Maximum borehole diameter [mm]
  • Impeller material
  • Construction
  • Check valve
  • Availability
  • Price

next

Variant Product No.

Availability

Price (VAT incl.)

Maximum flow [l/min]
25
Maximum head [m]
86
Input voltage [V]
230
Power output - P2 [kW]
0.37
Rated flow [l/m]
15
Rated head [m]
56
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
3.80
Maximum liquid temperature [°C]
35
Cable length [m]
30
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
25
Maximum head [m]
126
Input voltage [V]
230
Power output - P2 [kW]
0.55
Rated flow [l/m]
15
Rated head [m]
86
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
5.50
Maximum liquid temperature [°C]
35
Cable length [m]
2
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
25
Maximum head [m]
173
Input voltage [V]
230
Power output - P2 [kW]
0.75
Rated flow [l/m]
15
Rated head [m]
117
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
6.50
Maximum liquid temperature [°C]
35
Cable length [m]
2
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
25
Maximum head [m]
126
Input voltage [V]
230
Power output - P2 [kW]
0.55
Rated flow [l/m]
15
Rated head [m]
86
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
5.50
Maximum liquid temperature [°C]
35
Cable length [m]
30
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
25
Maximum head [m]
173
Input voltage [V]
230
Power output - P2 [kW]
0.75
Rated flow [l/m]
15
Rated head [m]
117
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
6.50
Maximum liquid temperature [°C]
35
Cable length [m]
30
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
25
Maximum head [m]
126
Input voltage [V]
230
Power output - P2 [kW]
0.55
Rated flow [l/m]
15
Rated head [m]
86
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
5.50
Maximum liquid temperature [°C]
35
Cable length [m]
40
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
25
Maximum head [m]
173
Input voltage [V]
230
Power output - P2 [kW]
0.75
Rated flow [l/m]
15
Rated head [m]
117
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
6.50
Maximum liquid temperature [°C]
35
Cable length [m]
40
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
25
Maximum head [m]
126
Input voltage [V]
230
Power output - P2 [kW]
0.55
Rated flow [l/m]
15
Rated head [m]
86
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
5.50
Maximum liquid temperature [°C]
35
Cable length [m]
50
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
25
Maximum head [m]
173
Input voltage [V]
230
Power output - P2 [kW]
0.75
Rated flow [l/m]
15
Rated head [m]
117
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
6.50
Maximum liquid temperature [°C]
35
Cable length [m]
50
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
50
Maximum head [m]
67
Input voltage [V]
230
Power output - P2 [kW]
0.55
Rated flow [l/m]
35
Rated head [m]
49
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
5.50
Maximum liquid temperature [°C]
35
Cable length [m]
2
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
50
Maximum head [m]
67
Input voltage [V]
230
Power output - P2 [kW]
0.55
Rated flow [l/m]
35
Rated head [m]
49
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
5.50
Maximum liquid temperature [°C]
35
Cable length [m]
30
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
You are viewing this variant
Maximum flow [l/min]
50
Maximum head [m]
67
Input voltage [V]
230
Power output - P2 [kW]
0.55
Rated flow [l/m]
35
Rated head [m]
49
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
5.50
Maximum liquid temperature [°C]
35
Cable length [m]
40
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
50
Maximum head [m]
67
Input voltage [V]
230
Power output - P2 [kW]
0.55
Rated flow [l/m]
35
Rated head [m]
49
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
5.50
Maximum liquid temperature [°C]
35
Cable length [m]
50
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
50
Maximum head [m]
92
Input voltage [V]
230
Power output - P2 [kW]
0.75
Rated flow [l/m]
35
Rated head [m]
49
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
6.50
Maximum liquid temperature [°C]
35
Cable length [m]
2
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
50
Maximum head [m]
92
Input voltage [V]
230
Power output - P2 [kW]
0.75
Rated flow [l/m]
35
Rated head [m]
67
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
6.50
Maximum liquid temperature [°C]
35
Cable length [m]
30
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
50
Maximum head [m]
92
Input voltage [V]
230
Power output - P2 [kW]
0.75
Rated flow [l/m]
35
Rated head [m]
67
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
6.50
Maximum liquid temperature [°C]
35
Cable length [m]
40
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
50
Maximum head [m]
92
Input voltage [V]
230
Power output - P2 [kW]
0.75
Rated flow [l/m]
35
Rated head [m]
67
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
6.50
Maximum liquid temperature [°C]
35
Cable length [m]
50
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
50
Maximum head [m]
139
Input voltage [V]
230
Power output - P2 [kW]
1.10
Rated flow [l/m]
35
Rated head [m]
101
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
8.50
Maximum liquid temperature [°C]
35
Cable length [m]
2
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
50
Maximum head [m]
139
Input voltage [V]
230
Power output - P2 [kW]
1.10
Rated flow [l/m]
35
Rated head [m]
101
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
8.50
Maximum liquid temperature [°C]
35
Cable length [m]
30
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
50
Maximum head [m]
139
Input voltage [V]
230
Power output - P2 [kW]
1.10
Rated flow [l/m]
35
Rated head [m]
101
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
8.50
Maximum liquid temperature [°C]
35
Cable length [m]
40
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
50
Maximum head [m]
139
Input voltage [V]
230
Power output - P2 [kW]
1.10
Rated flow [l/m]
35
Rated head [m]
101
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
8.50
Maximum liquid temperature [°C]
35
Cable length [m]
50
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
70
Maximum head [m]
72
Input voltage [V]
230
Power output - P2 [kW]
0.75
Rated flow [l/m]
45
Rated head [m]
54
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
6.50
Maximum liquid temperature [°C]
35
Cable length [m]
2
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
70
Maximum head [m]
72
Input voltage [V]
230
Power output - P2 [kW]
0.75
Rated flow [l/m]
45
Rated head [m]
54
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
6.50
Maximum liquid temperature [°C]
35
Cable length [m]
30
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
70
Maximum head [m]
72
Input voltage [V]
230
Power output - P2 [kW]
0.75
Rated flow [l/m]
45
Rated head [m]
54
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
6.50
Maximum liquid temperature [°C]
35
Cable length [m]
40
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
70
Maximum head [m]
72
Input voltage [V]
230
Power output - P2 [kW]
0.75
Rated flow [l/m]
45
Rated head [m]
54
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
6.50
Maximum liquid temperature [°C]
35
Cable length [m]
50
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
70
Maximum head [m]
106
Input voltage [V]
230
Power output - P2 [kW]
1.10
Rated flow [l/m]
45
Rated head [m]
77
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
8.50
Maximum liquid temperature [°C]
35
Cable length [m]
2
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
70
Maximum head [m]
106
Input voltage [V]
230
Power output - P2 [kW]
1.10
Rated flow [l/m]
45
Rated head [m]
77
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
8.50
Maximum liquid temperature [°C]
35
Cable length [m]
30
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
70
Maximum head [m]
106
Input voltage [V]
230
Power output - P2 [kW]
1.10
Rated flow [l/m]
45
Rated head [m]
77
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
8.50
Maximum liquid temperature [°C]
35
Cable length [m]
40
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal
Maximum flow [l/min]
70
Maximum head [m]
106
Input voltage [V]
230
Power output - P2 [kW]
1.10
Rated flow [l/m]
45
Rated head [m]
77
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
8.50
Maximum liquid temperature [°C]
35
Cable length [m]
50
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal

Product description

Characteristics

  • Stainless steel construction developed and manufactured for many years of trouble-free operation
  • All metal parts are made of 304 stainless steel
  • Heavy duty stainless steel discharge head with built-in check valve for
    long service life and easy installation
  • Motor mounting specifications according to the NEMA standard
  • High quality shaft bearings ensuring low friction and high wear resistance
  • The impellers are of the floating type made with the addition of Noryl material
  • Stainless steel screen preventing the ingress of sand and other foreign material

Use

  • Supplying residential buildings with drinking water from deep wells
  • Utility and industrial water supply
  • Irrigation and other agricultural applications
  • Pressure amplification in high-rise buildings

Technical Specifications

Maximum flow [l/min]
50
Maximum head [m]
67
Input voltage [V]
230
Power output - P2 [kW]
0.55
Rated flow [l/m]
35
Rated head [m]
49
Delivery port ["]
5/4
Pump diameter ["]
4
Maximum immersion depth [m]
80
Drinking water certificate
NO
Float switch
NO
Maximum current [A]
5.50
Maximum liquid temperature [°C]
35
Cable length [m]
30
Protection [IP]
68
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
integrated
Maximum borehole diameter [mm]
98
Impeller material
noryl
Construction
centrifugal

Product Safety Information

Company responsible for product safety:
PUMPA,a.s.
U Svitavy 54/1, Brno 618 00, CZ
e-mail: [email protected]